Heat exchanger headers, coils and condenser tubes often need the end closed before drilling and brazing branch tubes. A welded end cap risks leaks and heat distortion; TD-31050 cold-spins the end into a dome in one piece with the tube, and covers larger diameters (above Ø40) that the TD-31040 cannot.
![]() Heat exchanger coil | ![]() Copper tube closing samples | ![]() Spin-closed copper tube end |
Copper and stainless?
Steel, stainless, copper and aluminium tubes can be closed if the material is ductile enough; send samples for a trial closing.
Need a flat end?
See the TD-21025 flat-end closing machine.
How to get a quote?
Email tube OD, wall, material and end drawing to sales@tdco.com.tw.